66 kv substation training report pdf free

Industrial summer training report on uttar pradesh power corporation limited 2202 kv substation barahuwa gorakhpur submitted in partial fulfillment of the requirements for the award of degree of bachelor of technology in electrical engineering ee submitted by ashutosh srivastava. Distribution voltages are typically medium voltage, between 2. Distribution substations michigan technological university. Case study of power factor effect on 220 kv and 66 kv transmission lines from vajamangala 2206611 kv station ijsrdvol. Hv substation project brief history et bihl d i 1987 f th il ti f l hv mv d established in 1987 for the realization of complex hv, mv and lv projects. Qualifications pack comprises set of os, together with the educational, training and. This report describes my doctor of engineering internship experience with.

Any technicalcourseis incompletewithoutsome type of training. Moe45 mva,233 kvmobile substation 6 one 1 copy of the test report or its draft shall be handed over to each person witnessed the test. The test report shall be submitted officially two 2 copies to moe the soonest after execution of each test. Bus supports are the most basic structure found inside a substation. Sf6 breaker cal ed as maintenance free breaker, has simple construction. An electric substation is constituent of electrical transmission and distribution system. How can decide the mva rating of power transformer for. Pdf load flow analysis of 6611 kv substation using. A mini project report on operation and maintenance of 2202kv substation submitted in partial fulfillment for the award of the degree of bachelor of technology in electrical and electronics engineering submitted by v. Substation construction manual i reference ni000401r122 ver 3 ergon energy corporation limited abn 50 087 646 062 ergon energy queensland pty ltd abn 11 121 177 802 revision history version description of change date 1 initial version 250320 2 content revised and. We offer 11 kv, 33 kv, 66 kv and 2 kv substation supply installation work in gurgaon, dehi, ncr, haryana, rajasthan, and other parts of india. Sf6 gas has a high affinity of absorbing free electrons as its electronegativity is very high.

Report on industrial summer training on 220 kv substation 1. Background the construction of the new substation was the first step on the critical path of the convention center. Single line diagram of 11kv substation substation provides the energy supply for the local area in which the line is located. How can decide the mva rating of power transformer for substation like 2202, 266, 6633kv etc answer raju transformer is working only based on load. A 765400 kv substation is the highest grade system voltage for transmission in india.

Substation report 6611 kv research paper 2095 words. Download as pdf, 400200 kv substation 400200 kv substation design scribd. This job is again accomplished by suitable apparatus called substation. Dmes 0006dmrcetrgis01specifications for 66 kv gas insulated switchgear draft 28jan2014 page 6 of 17 1. This training program is designed to provide the student with basic information about circuit breakers that are used in substations and switchyards. To make way for the convention center this 66kv substation had to be relocated.

There are four 220 kv incoming feeders for this substation coming from. Its main purpose is to provide support for rigid bus as it travels though the substation. The substation rating is defined as per the power handling capacity, location and purpose of substation. The load flow analysis and simulation of 6611 kv distribution substation with the help of pscad software for maintaining the voltage profile of different buses and feeders of the substation is done. Case study of power factor effect on 220 kv and 66 kv. Its main function is to transform the voltage from high to low. Gasinsulated switchgear elk04 c, 145 kv xiangan torch substation, china english pdf leaflet protection cover for all types of position indicator english pdf leaflet gasinsulated switchgear enk, 72. Basics, maintenance, and diagnostics vii contents continued page 4. Halli substation is the optimal solution to the power factor problem as shown in figure 3. The main bus 33kv is connected to grid located at sector25, indiranagar, lucknow.

An ebook reader can be a software application for use on a computer such as microsofts free reader application. Pdf 64804198powergridtrainingreport sukhwinder sharma. Dlf at village bhagwanpur cable portion with 1200 mm sq xlpe 66 kv power cable 5. After completion of all factory tests, the contractor shall bind all test reports properly. The 220 kv grid substation at sarita vihar is a air insulated outdoor substation. In case of breakdown of electrical system, manual operation is. The input for a distribution substation is typically at least two transmission or subtransmission lines. Distribution substation a distribution substation transfers power from the transmission system to the distribution system of an area. Economical voltage rating has been categorised for different power range to be received thumb rule. Report on industrial summer training on 220 kv substation. No description of technical parameter unit data 1 nominal system voltage kv rms 33kv 2 maximum system voltage kv rms 36. D12ee68 has succesfully completed his report on visit at. At these secondary substations the voltage is further reduced to 100. The two main processors are of the type pdf 1170 with 756 kilobytes of main.

The course shows how arcs are extinguished in gasblast and gaspuffer breakers, and covers four types of breaker operating mechanisms. Now the transmission line first parallel connected with lightning arrester to diverge surge, followed by cvt connected parallel. Six week industrial training final free download as powerpoint. Aug 1, 2011 a construction of new 3311 kv primary substation. Six week industrial training final electrical substation transformer. The main function of the substation is to collect the energy transmitted at high voltage from the generating station and then reduce the voltage to an appropriate value for local distribution and gives facilities for switching. Practical training report on 2206611 kv substation eep.

Similarly near the consumers localities, the voltage may have to be stepped down to utilization level. Rigid bus is stiff and will not move around during weather events. Substation transformer relay free 30day trial scribd. Tapered tubular design is typically efficient and economical in deadend andstatic pole situations when compared to aisc standard shape structures. What is the criteria for selection of 33kv11kv or 66kv. A summer internship report at uttar pradesh power corporation limited. Maintenance and operation of an electrical substation of. Training report of 3311kv substation mohamdabad, tundla.

540 359 1119 1077 1095 1327 264 1243 393 1252 1402 792 647 1541 1458 543 790 469 109 94 205 1202 1226 1166 472 558 658 899 1319 1253 1046 787 106 1233 689 1014